OEM RL-A9 Touch
OEM RL-A9 Metal Touch Exit Switch Original price was: KSh 500.00.Current price is: KSh 400.00. ex VAT
Back to products
Ubiquiti UniFi AC In-Wall (UAP-AC-IW) Access Point
Ubiquiti UniFi AC In Wall UAP AC IW Access Point Original price was: KSh 27,000.00.Current price is: KSh 2,400.00. ex VAT

Free delivery in Nairobi CBD for orders of KES 20,000+. Otherwise, or outside the CBD, delivery starts from KES 300 — pay your chosen rider or courier on delivery.

OEM RL-A11 Non-Touch Exit Switch

Original price was: KSh 900.00.Current price is: KSh 700.00. ex VAT

(3 customer reviews)

OEM RL-A11 Non-Touch Exit Switch

ModelRL-A11
TypeNon-touch exit switch
SensingInfrared proximity
ApplicationHands-free RTE
BrandOEM

Shipping & Delivery

Delivery

We deliver to the address you provide. Nairobi CBD is often same-day on business days.

Nairobi CBD or Kenya-wide

Free CBD ≥ KES 20,000; else from KES 300

Warranty 1 year

More details

72-hour (3-day) returns

More details

Unbeatable offers

Black Friday Blowout!

Description

RL-A11 Non-Touch Exit Switch

The OEM RL-A11 Exit switch uses infrared proximity sensing for hands-free request-to-exit release. Users wave a hand near the faceplate to signal the access controller without physical contact. Security integrators deploy the A11 model in healthcare, food service, and cleanroom doors where touch surfaces are discouraged. The non-touch sensor reduces wear compared with mechanical paddles on very high cycle openings. Low-voltage wiring connects the proximity output to supervised controller inputs on maglock circuits. Electricians route cable from the door wall box to IO modules following manufacturer gauge and distance limits. The RL-A11 mounts at standard reach height with clear detection zone marking for occupants. Installers adjust detection range during commissioning so accidental triggers from foot traffic are minimized. Controller firmware maps proximity RTE to unlock timers, interlocks, and anti-passback policies. Facilities teams specify non-touch exits on laboratory and surgical suite doors with strict hygiene protocols. The sensor face suits indoor conditioned corridors rather than unprotected outdoor exposure. Access auditors include proximity RTE devices on life-safety egress checklists during annual reviews. Integrators document detection range settings on door hardware schedules for future service calls. Fire alarm panels shunt lock power during alarm events regardless of proximity switch activation state. The A11 generates momentary release signals; it does not store credentials or process card data. Head-end systems log RTE events when audit logging is enabled for security operations centers. Server room mantraps may use non-touch inner exits so technicians egress while carrying equipment. Quality control verifies detection at maximum range and confirms no false trips from HVAC airflow. Procurement catalogs the A11 under access control sensors alongside touch and mechanical exit options. Technicians test supervised wiring and input resistance before accepting door commissioning. Proximity technology eliminates moving springs that fatigue on doors with thousands of daily cycles. Maintenance cleans sensor lenses per facilities policy to maintain reliable infrared detection. Education campuses install non-touch exits on cafeteria and clinic doors with heavy traffic volume. Warehouse clean zones use A11 switches on garment and wash entry doors with glove protocols. Integrators pair proximity RTE with door position switches to verify physical unlock after signal. Programming includes hold-open inhibit when interlock logic blocks mantrap inner release incorrectly. The sensor housing fits standard back boxes used for readers and mechanical exit devices. Service trucks carry spare A11 units for same-day replacement when drift tests fail field calibration. Non-touch exits complement signage instructing users to wave hand within the marked detection zone. Low-current dry contacts suit 12 VDC and 24 VDC subsystems on common door controllers. Install crews complete sensor mounting during the same visit as lock power and reader termination. Retrofit projects replace worn paddle switches when existing wire maps support proximity inputs. Detection range adjustment accounts for wall reflectors and bright sunlight on glass-adjacent doors. Controller event logs help security staff separate proximity RTE from tailgate alarm conditions. Multi-tenant offices standardize on non-touch exits for consistent hygienic egress on shared floors. The RL-A11 SKU maps to inventory for maintenance contract replacements and new build rollouts. Integrators verify fire release shunt overrides proximity input during alarm panel functional tests. Proximity sensing supports users carrying trays, carts, or tools who cannot press a paddle. Technicians label each switch with wave icon decals matching manufacturer detection zone guidance. Access projects document A11 model on door elevation drawings for permit and inspection packages. Healthcare infection control teams prefer non-touch RTE on patient corridor doors with maglocks. The sensor does not require PoE; it uses discrete low-voltage pairs from the door controller. Commissioning includes walk-through tests with multiple users to validate range across hand sizes. Field supervisors apply first-door template settings before bulk commissioning on remaining openings. Non-touch technology reduces acoustic noise from repeated mechanical paddle strikes in quiet zones. Security integrators confirm compatibility with controller supervised input modules before bulk orders. The A11 suits pharmaceutical and electronics assembly doors with controlled environment requirements. Maintenance schedules include lens inspection and range re-test during annual access hardware audits.

Key Features

  • Infrared Proximity Detection
    Hand wave near the faceplate triggers request-to-exit without physical contact.

  • Hands-Free Hygienic Egress
    Non-contact actuation suits healthcare, food service, and cleanroom doors.

  • Adjustable Detection Range

    • Field tuning limits false triggers from pass-by foot traffic
    • Commissioning validates reliable wave detection at marked zone
  • Access Control Integration
    Dry contacts connect to door controllers for maglock and strike release.

Specifications

FeatureSpecification
ModelRL-A11 (A11)
Device TypeNon-touch exit / proximity RTE switch
Sensing MethodInfrared proximity
ActuationHands-free wave detection
Control Voltage12/24 VDC low-voltage contacts
BrandOEM
SKURL-A11

What’s in the Box

  • RL-A11 non-touch infrared exit switch

  • Mounting hardware for wall plate installation

Why Choose RL-A11

  • Hands-free proximity release supports hygienic egress on maglocked healthcare and lab doors.

  • No moving paddle parts reduces mechanical wear on very high traffic openings.

  • Adjustable range tuning minimizes false triggers during commissioning.

Customer Reviews

4.7
3 reviews
2
1
0
0
0

3 reviews for OEM RL-A11 Non-Touch Exit Switch

Clear filters
  1. Regina Odongo (verified owner) –

    Chose the no-touch exit switch for a lab corridor. Infrared trigger is consistent and staff like not pressing a grubby button. Mounting bracket aligned with standard back boxes.

  2. Tom Mwangi (verified owner) –

    A11 non-touch sensor — wave and the mag lock drops. Hygienic for hospital doors.

  3. Gilbert Kiprotich (verified owner) –

    Paired with an electric strike on a server room. Sensitivity is fine out of the box — no false triggers from people walking past. Clean install and good spec for access control upgrades.

Add a review

Your email address will not be published. Required fields are marked *