Mecer Winner Pro ME-6000-WPRU 6000VA 4800W Online Rackmount UPS
Original price was: KSh 269,396.55.KSh 217,241.38Current price is: KSh 217,241.38. ex VAT
Mecer Winner Pro ME-6000-WPRU 6000VA 4800W Online Rackmount UPS
| Capacity | 6000 VA / 4800 W |
| Topology | Online double conversion |
| Form factor | Rackmount |
| Nominal voltage | 230 V class |
Shipping & Delivery
Fast delivery
Your order will be deliver to the specified address
15 - 45 minutes
From KES 300

Warranty 1 year
Free 30-Day returns
Description
Mecer Winner Pro 6000VA Rack UPS
The Mecer ME-6000-WPRU is a Winner Pro online rackmount uninterruptible power supply rated at 6000 VA and 4800 W. Double-conversion topology regenerates a sine-wave output so servers and network cores do not ride raw utility during sags and frequency wander. The WPRU suffix denotes the rackmount Winner Pro chassis, as distinct from tower WPTU siblings in the same VA class. Input is typically hard-wired on 6 kVA online units. Confirm terminal layout, breaker size, and earth before energizing.
Additionally, 0.8 power factor yields 4800 W of real output from 6000 VA. Therefore size loads in watts, especially with high-PF server PSUs. However, internal battery runtime at full load is measured in minutes. Consequently, treat this unit as a ride-through and orderly-shutdown device unless extra battery cabinets are specified by Mecer for this chassis.
Key Features
Online double conversion
The inverter supplies the load continuously, isolating IT gear from incoming disturbances.6000 VA / 4800 W class
- Suits mid-size racks of servers, storage, and PoE switches.
- 0.8 PF is typical of this Winner Pro rating; do not assume unity PF.
Rackmount Winner Pro chassis
WPRU form factor mounts in a 19-inch rack. Use the correct rail depth and rear clearance for exhaust.LCD and communications
Front LCD plus USB/RS-232 style ports support local status and OS shutdown agents where software is provided.Bypass path
Online 6 kVA designs include bypass for maintenance when the utility path is within limits.
Specifications
| Feature | Specification |
|---|---|
| SKU | ME-6000-WPRU |
| Series | Mecer Winner Pro |
| Capacity | 6000 VA / 4800 W |
| Topology | Online double conversion |
| Form factor | Rackmount (WPRU) |
| Nominal voltage | 230 V class, 50/60 Hz |
| Waveform | Pure sine wave (online) |
| Power factor | 0.8 |
| Typical I/O | Hardwired on 6 kVA class (confirm on unit) |
| Batteries | Internal VRLA; runtime load-dependent |
| Management | LCD, USB / serial (model dependent) |
What’s in the Box
ME-6000-WPRU UPS
Rack hardware as packed
Communication cable as packed
User documentation
Why Choose This Rack UPS
Online conversion protects mixed IT loads on unstable mains.
4800 W real power is enough for many 12–24U branch racks.
Rackmount WPRU keeps the UPS in the same cabinet as the load.
LCD status reduces guesswork during commissioning.
Additionally, verify generator compatibility and bypass transfer settings. Therefore a site survey of earthing and breaker coordination is not optional at 6 kVA. However, do not overload the inverter with laser printers or inductive plant on the same string as servers. Consequently, split dirty loads onto a separate circuit. After install, run a controlled battery test at a known watt load and record autonomy.