EVI 2000VA / 1200W Line Interactive UPS with LCD Display and 4 Universal Outlets
| Model | EP-UPS2000UU2IE2-UK |
| Capacity | 2000 VA / 1200 W |
| Topology | Line interactive with boost and buck AVR |
| Input voltage range | 140 to 300 VAC |
| Output voltage | 230 VAC ±10% |
| Transfer time | 2 to 6 ms typical |
| Output connections | 4 x universal outlets |
| Battery | 2 x 12 V 9 Ah sealed lead-acid |
| Backup time | 10 to 30 minutes depending on load |
| Display | Multi-function LCD panel |
| Communication | USB with monitoring and control software |
| Warranty | 2 years unit, 1 year battery |
Same day Delivery
Delivery
We deliver to the address you provide. Nairobi is often same-day on business days.
Across the country
Delivery outside CBD starts from KES 300
Warranty 1 year
72-hour (3-day) returns
Description
Line Interactive Tower Backup for Office Loads
The EVI 2000VA UPS supplies 1200 W of conditioned backup power to workstations, network equipment and point-of-sale terminals. The line interactive topology adds boost and buck AVR stages that correct sags and swells without draining the battery. A multi-function LCD reports input voltage, load level and battery state at the front panel.
Four universal outlets accept UK, EU and US plugs, so mixed hardware connects without adapters. Transfer to battery takes 2 to 6 ms typical, and the simulated sine wave output suits the switched-mode supplies inside desktop PCs and monitors.
Two internal 12 V 9 Ah sealed lead-acid blocks deliver 10 to 30 minutes of runtime at partial load. Recharge to 90% capacity takes 6 to 8 hours. Cold start lets the unit switch on with no mains present, and the USB port links to the bundled monitoring application.
Key Features
Boost and Buck AVR Stages
The regulator corrects low and high mains voltage across a 140 to 300 VAC window before the inverter engages.Front Panel Instrumentation
- LCD shows input and output voltage in real time
- Load percentage and battery capacity bars
- Fault and overload status indicators
- Audible alarm for battery mode and low charge
Cold Start Function
The unit powers connected loads from battery with the mains disconnected, which suits field commissioning and staged rollouts.Monitoring and Control Software
- USB interface for host connection
- Scheduled shutdown and startup events
- Logged input voltage and load history
- Configurable alarm thresholds
Intelligent Battery Management
Charging logic limits current at high ambient temperature and blocks deep discharge to extend block service life.Surge and Overload Protection
Input surge clamping and output overload cut-off protect attached hardware during grid transients.
Specifications
| Feature | Specification |
|---|---|
| Model | EP-UPS2000UU2IE2-UK |
| Capacity | 2000 VA / 1200 W |
| Topology | Line interactive with boost and buck AVR |
| Input voltage range | 140 to 300 VAC |
| Input frequency | 50/60 Hz auto-sensing |
| Output voltage | 230 VAC ±10% |
| Output waveform | Simulated sine wave on battery |
| Transfer time | 2 to 6 ms typical |
| Output connections | 4 x universal outlets |
| Battery type | 12 V sealed lead-acid, maintenance-free |
| Battery configuration | 2 x 12 V 9 Ah internal |
| Backup time | 10 to 30 minutes depending on load |
| Recharge time | 6 to 8 hours to 90% capacity |
| Display | Multi-function LCD panel |
| Communication | USB port with monitoring and control software |
| Protection | Overload, surge and short circuit |
| Operating temperature | 0 to 40°C |
| Operating humidity | 0 to 90% RH, non-condensing |
| Form factor | Tower |
| Warranty | 2 years unit, 1 year battery |
What’s in the Box
UPS tower unit
USB interface cable
Monitoring and control software media
User documentation
Mains input cord
Why Choose EVI
The regulator holds output inside a 10% band through brownouts that would otherwise reboot desktop hardware.
Universal receptacles remove the need for plug adapters on mixed UK and EU equipment fleets.
Battery management logic extends block life in warm comms rooms where chargers typically overheat cells.
USB telemetry feeds host shutdown scripts, so servers and tills close cleanly before runtime expires.
Cold start support keeps commissioning work moving during building power isolation.




Brian Otieno (verified owner) –
Bought this for my home office in Kilimani after the last power cut cost me a client call. The 2000VA rating handles my PC, monitor and router without breaking a sweat. LCD shows load and battery clearly, so I know exactly where I stand. Two months in and no complaints.
Dennis Mwangi (verified owner) –
Works well for my small cyber cafe. The built-in AVR is the part I appreciate most because voltage swings here are brutal. Only note: the monitoring software is basic and the USB cable is short, so plan your desk layout. Still good value for a line interactive unit this size.
Wanjiru Kamau (verified owner) –
Delivery to Nakuru was quick and the unit was well packed. The four universal outlets take both my UK and Euro plugs without adapters, which saves clutter. Battery management seems solid so far.
Faith Achieng (verified owner) –
Cold start function saved me twice during outages. Solid build.
Kevin Omondi (verified owner) –
I run a small design studio in Westlands and needed something to keep my workstation and NAS alive through short outages. The 1200W real output is enough for my setup and the LCD gives me a quick read on battery capacity before a scheduled blackout. The boost and buck AVR has handled the voltage dips we get here without switching to battery, which is what I really wanted. The only thing I would change is the lack of a network card option for remote monitoring, but for a local unit this covers the job.
Njeri Muthoni (verified owner) –
Ordered for our church office in Thika. Powers the reception PC and printer through the Sunday service outages. The 2 year warranty gives us confidence. The monitoring software setup took a bit of figuring out but the unit itself has been stable.