Mecer Astro 2.2kW
Mecer Astro 2.2kW 380V 3-Phase VFD Original price was: KSh 20,300.00.Current price is: KSh 16,200.00. ex VAT
Back to products
Mecer Leoch DJW12-18
Mecer Leoch DJW12-18 12V 18Ah SLA Battery Original price was: KSh 18,600.00.Current price is: KSh 14,900.00. ex VAT

Free delivery in Nairobi CBD for orders of KES 20,000+. Otherwise, or outside the CBD, delivery starts from KES 300 — pay your chosen rider or courier on delivery.

Mecer Astro 3.7kW 380V 3-Phase VFD

Original price was: KSh 23,500.00.Current price is: KSh 18,800.00. ex VAT

(3 customer reviews)

Limited Stock

Mecer Astro 3.7kW 380V 3-Phase VFD

Rated Power3.7 kW
Input VoltageAC 3-phase 380V
Drive TypeVariable Frequency Drive
ModelAstro 3.7G-T4

Shipping & Delivery

Delivery

We deliver to the address you provide. Nairobi CBD is often same-day on business days.

Nairobi CBD or Kenya-wide

Free CBD ≥ KES 20,000; else from KES 300

Warranty 1 year

More details

72-hour (3-day) returns

More details

Unbeatable offers

Black Friday Blowout!

Description

Astro 3.7kW VFD

The Mecer Astro 3.7kW variable frequency drive provides 3.7 kilowatts of adjustable AC motor output from a three-phase 380V supply. This drive targets medium-duty industrial applications where motor speed must track process demand rather than run at fixed synchronous speed. Facilities managers and controls engineers deploy Astro series units to improve energy efficiency on equipment that operates below peak capacity for significant portions of each shift.

At 3.7 kW rated output, this unit handles larger centrifugal pumps, compressor auxiliaries, and material handling motors than the 2.2 kW sibling in the same product family. The T4 designation in the model code identifies the voltage class and frame configuration within the Astro lineup. Integration follows standard VFD practices: mount in a ventilated enclosure, wire input through appropriate protection, and connect motor leads to the output terminals with shielded cable where EMI sensitivity exists.

Parameter setup covers acceleration and deceleration ramps, minimum and maximum frequency limits, and fault protection thresholds. These settings prevent overcurrent trips during rapid load changes and protect both the drive and the connected motor from thermal damage. Maintenance teams benefit from diagnostic LED indicators and fault code readouts that speed troubleshooting during production downtime.

Quadratic loads such as fans and pumps follow affinity laws where power drops sharply as speed decreases. Running a 3.7 kW motor at seventy percent speed can cut electrical demand by roughly sixty-five percent compared with damper or valve throttling at full motor speed. Document baseline energy readings before and after VFD installation to quantify savings for facility audits.

Braking requirements on high-inertia loads may need an external braking resistor to dissipate regenerative energy during fast deceleration. Verify whether the application demands controlled stop times that exceed the drive’s internal DC injection braking capacity. Motor cable length affects voltage reflection; follow manufacturer guidance on maximum run length or install output reactors when routing exceeds recommended distances.

Commissioning includes direction verification, no-load spin test, and loaded ramp validation across the intended speed range. Record final parameter sets in the site maintenance log so replacement drives restore identical behavior without re-tuning from scratch. Pair this unit with contactors or bypass arrangements only when code or operational policy requires maintenance isolation independent of the inverter stage.

Key Features

  • 3.7 kW Continuous Rating
    Supports motors rated up to 3.7 kW for sustained industrial duty cycles.

  • 380V Three-Phase Input
    Connects directly to standard industrial three-phase distribution without voltage conversion.

  • Speed and Torque Regulation

    • Variable output frequency from near-zero to motor base speed and above
    • Maintains usable torque across the programmed speed range for load types within drive rating
  • Process Application Support

    • Water circulation pumps in HVAC and irrigation systems
    • Exhaust and supply fan speed modulation in ventilation networks
    • Conveyor belt rate control in packaging and assembly lines
  • Energy Reduction Capability
    Lowering motor speed on quadratic-load applications such as fans and pumps reduces power draw proportionally to speed cubed.

Specifications

FeatureSpecification
BrandMecer
ModelAstro 3.7G-T4
Rated Power3.7 kW
Input VoltageAC 3-phase 380V
Drive TypeVariable Frequency Drive (VFD)
ApplicationAC induction motor speed control
SKUASTRO-3.7G-T4

What’s in the Box

  • Mecer Astro 3.7G-T4 variable frequency drive unit

  • Installation and operation documentation

Why Choose Astro 3.7kW VFD

  • 3.7 kW rating covers a common motor size in commercial and light industrial plants

  • Three-phase 380V input matches regional industrial electrical standards

  • Variable speed control replaces mechanical throttling devices on pump and fan circuits

  • Programmable ramps reduce mechanical wear during frequent start-stop cycles

  • Part of the Mecer Astro family for consistent spare parts and parameter knowledge across sites

Customer Reviews

4.3
3 reviews
1
2
0
0
0

3 reviews for Mecer Astro 3.7kW 380V 3-Phase VFD

Clear filters
  1. Benson Kariuki (verified owner) –

    variable frequency drive cut our energy bill on the fan wall

  2. Priscilla Mwangi (verified owner) –

    astro 3.7g for 3phase motor, electrician said wiring was clean

  3. Kelvin Otieno (verified owner) –

    3.7kW vfd on bigger compressor, holds speed under load well

Add a review