Free delivery in Nairobi CBD for orders above KES 20,000
Siemon Cat 6A Patch Cord 1m S/FTP 26AWG LSZH Shielded
Original price was: KSh 2,100.00.KSh 1,700.00Current price is: KSh 1,700.00. ex VAT
Siemon Cat 6A Patch Cord 1m S/FTP 26AWG LSZH Shielded
| Category | Category 6A |
| Construction | S/FTP shielded |
| Conductor | 26 AWG stranded tinned copper |
| Length | 1m |
| Connector | RJ-45 to RJ-45 |
| Outside Diameter | 6.35 mm |
| Jacket | LSZH |
| Bend Radius | 50 mm |
| Performance | ANSI/TIA-568.2-D, ISO/IEC 11801 Class EA |
| Operating Temperature | -20°C to +75°C |
Same day Delivery
Delivery
We deliver to the address you provide. Nairobi is often same-day on business days.
Across the country
Delivery outside CBD starts from KES 300
Warranty 1 year
72-hour (3-day) returns
Description
Shielded Cat6A Modular Cord
The Siemon Cat 6A patch cord combines an S/FTP construction with a PCB-based Smart Plug to hold Category 6A performance across a 1m run. Stranded 26 AWG conductors survive repeated patching, and the LSZH jacket limits smoke output in occupied rooms. Factory testing verifies each assembly against ANSI/TIA-568.2-D and ISO/IEC 11801 Class EA limits.
Each pair sits inside an aluminium foil screen, and an overall braid rejects alien crosstalk from adjacent cables. The Smart Plug PCB tunes signal integrity at the interface, which removes the variability of crimp-style terminations. Fixed front contacts maintain consistent mating with RJ-45 outlets, and rear contacts preserve cable twist to the point of termination.
A low-profile boot keeps side stackability high in dense patch fields, and the cantilevered latch releases from further back on the boot. The 6.35 mm cable outside diameter routes through standard cable managers, and the 50 mm bend radius protects Cat6A return loss and NEXT margins. Removable colour clips allow field coding without disconnecting the cord.
Deploy this shielded Cat6A patch lead in data centres, blade server enclosures, and enterprise racks that carry 10GBASE-T or PoE loads. The S/FTP screen also supports HDBaseT and other shielded applications where alien crosstalk threatens link stability. Operating temperature spans -20°C to 75°C, and the assembly meets IEC 60603-7 and IEC 61156-5 connector and cable requirements.
Key Features
Smart Plug PCB Termination
An integrated circuit board tunes impedance and crosstalk at the plug interface for stable Category 6A margins.S/FTP Shielded Construction
Foil-screened pairs and an overall braid suppress alien crosstalk in high-density patching areas.26 AWG Stranded Conductors
- 7×32 stranded tinned copper survives repeated flexing
- 6.35 mm nominal outside diameter fits standard pathways
- LSZH jacket meets CM and low-smoke halogen requirements
Low-Profile Boot and Latch
The compact boot improves side stackability, and the cantilevered latch releases from the rear of the plug.50 mm Bend Radius
The boot enforces a bend radius critical for maintaining Cat6A return loss under load.Factory Tested
Every cord passes 100% performance testing to ANSI/TIA-568.2-D and ISO/IEC 11801 Class EA.Removable Colour Clips
Optional clips allow field colour coding without unplugging the cord from the outlet.
Specifications
| Feature | Specification |
|---|---|
| Category | Category 6A (Augmented Category 6) |
| Cable Construction | S/FTP (screened foiled twisted pair) |
| Conductor | 26 AWG 7×32 stranded tinned copper |
| Length | 1m |
| Connector | RJ-45 to RJ-45, shielded |
| Wiring | T568A/B compatible |
| Nominal Outside Diameter | 6.35 mm |
| Jacket Material | LSZH |
| Boot Type | Clear low-profile |
| Bend Radius | 50 mm |
| Frequency Range | 1 MHz to 500 MHz |
| Supported Applications | 10GBASE-T, 1000BASE-T, PoE, HDBaseT |
| Performance Standard | ANSI/TIA-568.2-D, ISO/IEC 11801 Class EA |
| Connector Standard | IEC 60603-7, IEC 60603-7-41 |
| Cable Standard | IEC 61156-5 |
| Operating Temperature | -20°C to +75°C |
| PoE Rating | IEEE 802.3af / 802.3at / 802.3bt compatible |
What’s in the Box
1m Siemon Z-MAX Cat6A S/FTP patch cord, clear boot
Why Choose This Shielded Cord
The PCB-based plug removes crimp variability and holds Class EA margins across the mated interface.
S/FTP screening protects 10GBASE-T links from alien crosstalk in crowded racks.
The 50 mm bend radius preserves return loss when cords dress tightly around cable managers.
LSZH jacketing suits data halls, risers, and air-handling spaces.
Factory testing covers every assembly, so commissioning does not require field loss verification.
The low-profile boot and rear-release latch speed moves and changes in high-density patching.




Michael Otieno (verified owner) –
Shielded build feels solid. No interference on the link.
Jane Wambui (verified owner) –
Imefika vizuri
David Kimani (verified owner) –
Works well.
Rose Anyango (verified owner) –
Sawa
Patrick Mwenda (verified owner) –
1m length perfect for the switch to panel run
Lucy Nduta (verified owner) –
Clips hold tight in the patch panel
George Onyango (verified owner) –
Good