Get free delivery within Nairobi CBD for orders above KES 20,000
APC Smart-UPS SRT 5000VA 230V 4.5kW Online Double-Conversion SRT5KXLI
Original price was: KSh 484,137.93.KSh 413,793.10Current price is: KSh 413,793.10. ex VAT
APC Smart-UPS SRT 5000VA 230V 4.5kW Online Double-Conversion SRT5KXLI
| Capacity | 5000 VA / 4500 W |
| Topology | Double-conversion online |
| Nominal voltage | 230 V (220 / 240 V) |
| Waveform | Pure sine wave |
| Form factor | Rack / tower convertible |
Shipping & Delivery
Fast delivery
Your order will be deliver to the specified address
15 - 45 minutes
From KES 300

Warranty 1 year
Free 30-Day returns
Description
APC Smart-UPS SRT 5000VA
The APC SRT5KXLI UPS is a double-conversion online uninterruptible power supply rated at 5000 VA and 4500 W for 230 V single-phase loads. Continuous rectifier and inverter operation isolates servers, storage, and voice gear from sags, surges, and frequency drift. The output remains a low-distortion sine wave while the input is hard-wired 3-wire (1P+N+E). The chassis converts between tower feet and a 3U rack mount when a compatible rail kit is fitted. Network management, USB, serial, and a SmartSlot path support local and remote monitoring.
Additionally, the unit holds a wide input window so it stays online through unstable utility conditions. Therefore connected loads see fewer transfers to battery on typical East African feeders. However, full-load runtime on internal batteries is short by design. Consequently, sites that need longer hold-up should plan matching external battery packs rather than oversizing VA alone.
Key Features
Double-conversion online topology
The inverter runs continuously, so the load never rides raw mains during a disturbance.High real-power rating
- 5000 VA / 4500 W supports dense 230 V IT loads.
- Power factor near 0.9 delivers more watts than many line-interactive 5 kVA units.
Hardwired input and mixed IEC outlets
Input is 3-wire hardwire. Output includes six IEC C13, four IEC C19, and two IEC jumpers.Internal automatic and manual bypass
Bypass keeps loads powered during service when the bypass path is healthy.Extendable runtime
Hot-swappable lead-acid modules and SRT192BP cabinets extend autonomy without changing the electronics.
Specifications
| Feature | Specification |
|---|---|
| Model / SKU | SRT5KXLI |
| UPS type | Double conversion online |
| Rated power | 5000 VA / 4500 W |
| Nominal input / output | 230 V (220 / 240 V supported) |
| Waveform | Pure sine wave |
| Output distortion | Less than 2% |
| Crest factor | 3:1 |
| Input connection | Hardwire 3-wire (1P+N+E) |
| Input range (main) | 160–275 V (100–275 V at half load) |
| Input frequency | 40–70 Hz auto-sensing |
| Output connections | 6× IEC C13, 4× IEC C19, 2× IEC jumpers |
| Bypass | Internal automatic and manual |
| Battery | Sealed lead-acid; replacement APCRBC140 |
| Battery voltage | 192 V nominal |
| Typical recharge | About 1.5 hours to recoverable charge |
| Expected battery life | 3–5 years (duty dependent) |
| Communications | USB, serial, Ethernet / SmartSlot, EPO |
| Dimensions (H×W×D) | Approx. 432 × 130 × 719 mm |
| Net weight | Approx. 54.4 kg |
| Heat dissipation | About 931 BTU/h |
| Audible noise | About 55 dBA |
| Operating temperature | 0–40 °C |
What’s in the Box
SRT5KXLI UPS chassis
Removable tower support feet
USB and serial cables
Temperature probe
IEC jumper cables as supplied
Documentation and warranty card
Rail kits for 19-inch racks are typically ordered separately. Confirm the matching APC rail SKU before a rack install.
Why Choose This Online UPS
True online conversion protects active-PFC servers without a transfer gap.
4500 W real output supports denser racks than many 5 kVA line-interactive units.
Hardwired input and mixed IEC outlets fit plant rooms and network closets on 230 V.
Scalable battery cabinets let autonomy grow with recovery-time objectives.
LCD and network-management options simplify commissioning and remote fault response.
Additionally, output frequency can sync to the mains within a tight window when utility conditions allow. Therefore generator and ATS designs remain workable when transfer characteristics are engineered correctly. However, cables, breakers, and ventilation must match nameplate current and heat. Consequently, installation should follow Schneider Electric APC documentation and local electrical code. Place the unit with clear rear exhaust, torque the hardwire lugs, and test bypass before placing production loads on the outlets.
See more APC UPS under uninterruptible power supplies.






























Reviews
Clear filtersThere are no reviews yet.